China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-OTR-1903 Oxygen Permeability Tester

Xtester-OTR-1903 Oxygen Permeability Tester

2023-07-21 09:37:35  

OTR-1903 Oxygen Permeability Tester

  • Main Features :
  • Serial No. :

Contact US For Quotation 

 Email:mewoi009@mewoi.com  Whatsapp&Wechat:+8619925688679

Application

OTR-1903 is based on the coulometric sensor method and available for the OTR test of flexible films, sheeting and packages.

Features

Coulometric sensor method
Own technology
Film and package test
one piece specimen test
One-button test, test automatically in whole process
Multiple test modes optional
Data curves display
Computer control
Digital flow adjustment
Chamber with temperature sensor embedded in
Environment temperature and humidity sensor inside
Chambers with water bath temperature control technology
Unit based on embedded system,24bit Δ-Σ AD
Pressure, oxygen and  temperature overload protection
Traceable reference film calibration
Supports DSM system (DSM, lab data management system)

   Technical

Test range
Film:  0.01-6300 cm3/m2·d (Standard)
0.07-6,3000 cm3/m2·d (Optional)

Resolution: 0.001 cm3/m2·d

Package:0.0001~62 cm3/pkg·d

Resolution: 0.00001 cm3/m2·d


Specimen amount
one piece
Temperature range
5C – 95C (with temperature controller)
Temperature accuracy
±0.1C
Humidity range
0%RH,35%RH-90%RH,100%RH
Humidity accuracy
±1%RH
Test area
50cm2
Specimen size
Film:  size:>=150mm * 94mm; thickness: less 1mm
Package: max size: D120mm * 400mm
Carrier gas
99.999% Nitrogen
Carrier flow
0~200ml/min
Gas interface
1/8inch
Power supply
AC 220V 50Hz
Dimension
330mm(L) * 600mm(W) * 330mm(H)
Net weight
28kg

   Standard

ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, GB/T 19789,

JIS K7126-B, YBB 00082003

   Configuration

Delivery: Main unit, computer, OX-TRANS software, tank regulator, PCIE card, communication cable, sample cutter, vacuum grease.

Optional: Temperature controller, package fixtures, reference film, vacuum grease, sample cutter, DSM system.


Note: Specifications are subject to change without prior notice.

Specification Selection Table

ModelOTR-1901OTR-1903
Test range

Film:  0.01-6500 cm3/m2·d (Standard)
0.07-6,5000 cm3/m2·d (Optional)
Resolution: 0.001 cm3/m2·d
Package:0.0001~62 cm3/pkg·d
Resolution: 0.00001 cm3/m2·d

Film:  0.01-6300 cm3/m2·d (Standard)
0.07-6,3000 cm3/m2·d (Optional)
Resolution: 0.001 cm3/m2·d
Package:0.0001~62 cm3/pkg·d
Resolution: 0.00001 cm3/m2·d

Specimen amount3 specimens, independentone piece
Humidity range0%RH,35%RH-90%RH,100%RH0%RH,35%RH-90%RH,100%RH
Test area50cm²50cm²
Specimen sizeFilm:  size:>=150mm * 94mm; thickness: less 1mm
Package: max size: D120mm * 400mm
Film:  size:>=150mm * 94mm; thickness: less 1mm
Package: max size: D120mm * 400mm
Dimension730mm(L) * 590mm(W) * 350mm(H)330mm(L) * 600mm(W) * 330mm(H)
Net weight57kg28kg


Telephone
Email
Map
QQ Chat