China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-  HZ-B Cable Fault Determination Pinpoint Tester Power Cable Fault Pinpointer
Xtester-  HZ-B Cable Fault Determination Pinpoint Tester Power Cable Fault Pinpointer
Xtester-  HZ-B Cable Fault Determination Pinpoint Tester Power Cable Fault Pinpointer
Xtester-  HZ-B Cable Fault Determination Pinpoint Tester Power Cable Fault Pinpointer

Xtester- HZ-B Cable Fault Determination Pinpoint Tester Power Cable Fault Pinpointer

2025-04-10 16:37:51  

HZ-B Cable Fault Determination Pinpoint Tester Power Cable Fault Pinpointer

  • Main Features :
  • Serial No. : Zoe728
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

HZ-B Cable Fault Determination Pinpoint Tester Power Cable Fault Pinpointer

 

Technical characteristics

Ultra-quiet noise reduction processing, excellent sound quality of discharge sound, the background is quieter, monitor earphones are used to quickly and reliably locate the fault location.

 Using ultra-quiet technology and BNR intelligent background noise reduction technology, you can adjust the impact discharge volume.

 Molded design of a special self-falling ground sensor, and equipped with a soft pavement, hardened pavement, lawn sensor joint.

Reliable imported connectors are selected to ensure the purity of the sound, and the height-adjustable probe handle is humanized, which is very suitable.

 

Technical parameter:

Sensor dynamic range: sound channel> 104dB.

 The impact discharge sound amplification factor > 90dB, and the upper limit of impact discharge volume is 84dB (A).

 Liquid crystal display: high-bright true color screen, 320 x 240 pixels, suitable for outdoor.

 Continuous working time on site: Alkaline replaceable battery, convenient for on-site use

1. Standard configuration:

· One receiver host, model HZ-B, with shoulder strap

· A sensor (ground microphone).

· One height-adjustable handle, height range 450 – 750 mm

· One headphone with sound quality

· One signal line, connecting the main unit of the receiver with the sensor, 1.20 m long

· One hard ground probe, 18 mm long

· One grass probe, 75 mm long

· 6 alkaline batteries of type 5, type IEC R6

· A manual

 

Dimension

 

32*24*13cm

 

Weight

2.5kg

 

 HZ-B (1).jpg

 


Telephone
Email
Map
QQ Chat