China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester- HT-LA433 Oxygen Analyzer

Xtester- HT-LA433 Oxygen Analyzer

2025-05-02 19:02:32  

HT LA433 Oxygen Analyzer

  • Main Features :
  • Serial No. : Zoe739
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

HT-LA433 Oxygen Analyzer

 

Technical Specifications

  • Measurement Principle: Zirconia

  • Display Mode: 320×240 dot matrix color LCD

  • Measurement Range: 0~10/100/1000PPm/1.00%/25.00% O_

  • Measurement Accuracy

  • 0~1000PPm/1.00%/25.00%: ≤±1%FS

  • 0~100PPm: ≤±2%FS

  • 0~10PPm: ≤±5%FS

  • Resolution

  • Trace: 0.1PPm

  • Normal: 0.01%

  • Repeatability: ≤±1.0%FS

  • Output Port

  • 4 - 20mA (Non - isolated output, load resistance<1KΩ)

  • 0 - 10V.DC (Non - isolated output, load resistance>10KΩ)

  • 2 ways of programmable alarm output (Dry contact type, maximum load 220V/2A)

  • 1 way of error alarm output

  • Communication Mode: RS232 (default) or RS485

  • Power Supply: AC88~264V 50/60Hz, power dissipation<25VA

  • Environment Temperature: -10°C~+50°C

  • Storage Environment Humidity: <90%RH, non - condensing

  • Operation Environment Humidity: <100%RH, non - condensing

  • Sample Gas Temperature: 0°C~60°C

  • Sampling Mode: Gas in

  • Sample Gas Flow: 400~600mL/min

  • Gas Inlet Pressure: 5Kpa≤ relative pressure≤200Kpa (relief valve is recommended if the pressure >200Kpa)

  • Gas Outlet Pressure: Free venting (under safe conditions)

  • Background Gas: N_ or other inert gas

  • Sensor Service Life: >5 years (under normal conditions of use)

  • Gas Circuit Port: NPT 1/8 internal thread

  • Instrument Weight: Net weight 3.1Kg

  • Installation Method: Embedded mounting


Features

a. Friendly communication menu enables intuitive and convenient operation.
b. 320×240 graphic dot - matrix color LCD display for clear viewing.
c. Original imported zirconia sensor consumes no service life when powered off, and features high measurement accuracy, rapid response speed and small zero - drift value.
d. Can operate in air for a long time without shortening the sensor's service life.
e. Allows multi - point fractional linear calibration to meet the need for accurate oxygen content measurement across the full range.
f. Has a rapid response speed and can measure down to 0.1PPm.
g. Automatic temperature and pressure compensation reduces the impact of environmental temperature and pressure changes on measurement accuracy.
h. Can automatically store 40,000 pieces of historical data locally for easy access at any time.
i. RS232 (default) or RS485 digital communication port can be selected according to customer requirements for unidirectional or bidirectional communication with computers or other digital communication facilities.


 


Telephone
Email
Map
QQ Chat