  • Main Features : Xtester125L High Accuracy Split Type Current Sensor Probe
  • Serial No. :

Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

INTRODUCTION

Xtester125L Split Type High Accuracy Leakage current Sensoris used for measurement of high accuracy AC current, leakage current, high order harmonic current, phase, power energy, power, power factor. Adopt the latest CT technology. It is portable, large clamp design, no need to disconnect the measured circuits, non-contact, safe and fast. It can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, harmonic analyzer, electric power quality analyzer, high precision digital multi-meter, etc. Widely applied in electricity, communication, meteorology, railway, oilfield, construction, measurement, scientific and research teaching unit, industrial and mining enterprises.Xtester125L Split Type High Accuracy Leakage current Sensor’score is made of special alloy, adopt the double magnetic shielding techniques, can almost shield the influence from external magnetic field, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement.

TECHNICAL SPECIFICATION

FunctionMeasurement of AC current, leakage current, high order harmonic current, phase, power energy, power, power factor
Test modeSplit Type CT
CT SizeΦ25mm(available for line $25mm)
Range0.000mA~60A (AC)
Resolution1uA (AC)
Accuracy±1.0%FS(23℃±2℃, below 70%RH, keep the wire be in the center of clamp)
Coils TurnStandard 800:1(Customize is allowed)
Phase Error≤2℃(50Hz/60Hz; 23℃±2℃)
Reference LoadRL: 0~600mA≤100ohm; 0-6A≤10ohm; 0-60A≤1ohm;
Output ModeCurrent induction output(Take the voltage can be an external load resistance (RL)
Output Interface3.5mm audio plug(tail plug, banana pin, or BNC pin)
Output Wire Length2m(Customize is allowed)
Electric Field InterferenceAbout 5mA when the external electric field 100A, 10mm nearby
Measured Wire PositionApproximately in the center of the closed core
Current Frequency45HZ-60Hz(when measuring big current)
Frequency Feature10Hz~100kHz
Voltage of circuitBelow AC 600V
Dimension78mmx64mmx31mm
WeightAbout 200g
Working Environment-20℃ ~ 50℃; below 80%rh
Storage Environment-10℃ ~60℃; below 70%rh
Insulation StrengthAC 2KV/rms.(between the core and shell)
Safety RulesIEC1010-1,IEC1010-2-032,Pollution degree:2 CAT Ⅲ(600V)

Split Type Current Sensor Probe

Click "Blue" marked Model No. to view the Spec


Model No.RangeClamp SizeResolutionCoils TurnCurrent induction output,Direct Coil tapDouble shielding, anti-jamming capability, suitable for leakage current, small current test
Xtester110LMEWOI110L.001.80.jpg0.000mA~ 60(AC)Φ10mm 1uA, Accuracy 1%1:800
Xtester110LEMEWOI110LE.80.jpg0.0mA~ 100mA(DC)Φ10mm 0.1mA, Accuracy 3%1:800
Xtester125LMEWOI125L.80.001.jpg0.000mA~ 60(AC)Φ25mm 1uA, Accuracy 1%1:800
Xtester125LEMEWOI125LE.80.001.jpg0mA~ 100mA(DC)Φ25mm 1mA, Accuracy 3% 1:800
Xtester140LMEWOI140L.80.jpg0.00mA~ 200(AC)Φ40 mm 10uA, Accuracy 1%1:800
Xtester140LEMEWOI140LE.80.002.jpg0mA~ 100mA(DC)Φ40 mm 1mA, Accuracy 3%1:800
Xtester185LMEWOI185L.80.jpg0.000mA~60A(AC)85*20mm 1uA, Accuracy 1%1:800