| Contact Us for Quotation | Email: mewoi008@mewoi.com | Whatsapp:+8619928420370 | 
Xtester-DP235 (35MHZ,1300Vp-p)differential probe
INTRODUCTION
Xtester-DP-235 - Two-stage attenuator switch for easier selection. - Special for high horsepower, maximum measuring voltage up to 2600Vp-p.- Can be used with any brand oscilloscope. - Power adapter. - Use standard oscilloscope USB slot to access 5V DC power supply.  | ||
Technical Specification
Model  | Xtester-DP-235  | 
Bandwidth(-3dB)  | DC-35MHz  | 
Accuracy  | ±2%  | 
Attenuation ratio  | X50/X500  | 
Rise time  | 10ns  | 
Voltage Input Ranges(DC+ Peak AC)  | ±1300V@500(1838Vrms) ±130V@50(183Vrms)  | 
Permitted Max. Input voltage  | Max differential voltage:±1300V(DC+ACpeak)  | 
Max voltage between each input terminal and ground  | 919Vrms  | 
Input Impedance  | 5MΩ//2pF each side to ground  | 
Output voltage  | ≤±2.6V  | 
Output impedance  | 50Ω(for 1 MΩ input oscilloscope)  | 
Rejection Rate on common mode  | 60Hz:>80dB/100Hz:>60dB/1MHz:>50dB  | 
5 MHZ Limit Bandwidth  | Switchable: Full / 5MHz  | 
Power supply  | External 5 V DC (USB Input)  | 
consumption  | 300mA  | 
Weight  | 285g  | 
Dimension (L×W×H)  | 175x68x28mm  | 
Selection Guide
| Model | Xtester-DP-235 | Xtester-DP-270 | Xtester-DP-210 | 
| Bandwidth | DC-35MHz(-3dB) | DC-70MHz(-3dB) | DC-100MHz(-3dB) | 
| Rise time | 10ns | 5ns | 3.5ns | 
| Attenuation Ratio | x50,x500 | ||
| Accuracy | ±2%(Heat engine in 20 minutes) | ||
| Input voltage range | x50≤260V x500≤2600V | ||
| Input AC Vp-p | 2600Vp-p | ||
| Input DC Voltage | 1300V | ||
| Input terminal and ground terminal maximum voltage | 919Vrms | ||
| Output voltage | ±2.6V | ||
| Noise suppression ration | 60Hz:>80dB/100Hz:>60dB/1MHz:>50dB | ||
| Input impedance | 10MΩ/1pF | ||
| Output impedance | 50Ω | ||
| 5MHz limited bandwidth | Switchable: Full/5MHz | ||
| Power | Specify an external 5V DC power supply | ||
| Max.conumption | 300mA | ||
| Dimension(LxWxH) | 175x68x28mm | ||
| Weight | 285g | ||
                English